Installation and Configuration Guide > Part II: Before You Install the Services > Before You Begin > Run the Pre-Installation (i10Pi) System Check Tool
  

Run the Pre-Installation (i10Pi) System Check Tool

Run the Pre-installation (i10Pi) System Check Tool to verify whether the machine meets the system requirements for installation or upgrade.
Ensure that you verified the system requirements and prepared the domain configuration repository database.
    1. Log in to the machine with a system user account.
    2. Close all other applications.
    3. On a shell command line, run the install.sh file from the root directory.
    The installer displays the message to verify that the locale environment variables are set.
    4. If the environment variables are not set, press n to exit the installer and set them as required.
    If the environment variables are set, press y to continue.
    5. Press 1 to install or upgrade Informatica.
    6. Press 1 to run the Pre-Installation (i10Pi) System Check Tool that verifies whether the machine meets the system requirements for the installation or upgrade.
    7. From the Informatica Pre-Installation (i10Pi) System Check Tool Welcome section, press Enter.
    The System Information section appears.
    8. Type the absolute path for the installation directory.
    The directory names in the path must not contain spaces or the following special characters: @|* $ # ! % ( ) { } [ ] , ; '
    Note: Informatica recommends using alphanumeric characters in the installation directory path. If you use a special character such as á or €, unexpected results might occur at run time.
    9. Press Enter.
    10. Enter the starting port number for the node that you will create or upgrade on the machine. The default port number for the node is 6005.
    11. Press Enter.
    The Database and Connection Information section appears.
    12. To enter the JDBC connection information using a custom JDBC connection string, press 1. To enter the JDBC connection information using the JDBC URL information, press 2.
    To connect to a secure database, you must enter the JDBC connection using a custom JDBC connection string.
    13. Enter the JDBC connection information.
    The tool checks the settings of the hard drive, the availability of the ports, and the configuration of the database. After the system check is complete, the System Check Summary section displays the results of the system check.
    14. Analyze the results of the system check.
    Each requirement is listed, along with one of the following check statuses:
    The results of the system check are saved to the following file: .../Server/i10Pi/i10Pi/en/i10Pi_summary.txt
    15. Press Enter to close the Pre-Installation (i10Pi) System Check Tool.
    You can continue to the Informatica service installation or upgrade immediately or end the system check and continue with the installation or upgrade later. If you continue to the installation or upgrade immediately, you do not have to restart the installer.
    16. To continue to the Informatica service installation or upgrade immediately, press y.
    To end the system check and continue with the installation or upgrade later, press n.
If the Pre-Installation (i10Pi) System Check Tool finishes with failed requirements, resolve the failed requirements and run the Pre-Installation (i10Pi) System Check Tool again.
Note: If the Informatica Pre-Installation (i10Pi) System Check Tool check finishes with failed requirements, you can still perform the Informatica installation or upgrade. However, Informatica highly recommends that you resolve the failed requirements before you proceed.